| 1.1 |
Date updated: |
Feb 25, 2010 |
| 1.2 |
Vessel's name: |
Nord Stream |
| 1.3 |
IMO number: |
9265689 |
| 1.4 |
Vessel's previous name(s) and date(s) of change: |
Not Applicable |
| 1.5 |
Date delivered: |
Apr 10, 2003 |
| 1.6 |
Builder (where built): |
Shin Kurushima Dockyard Co., Ltd |
| 1.7 |
Flag: |
Panama |
| 1.8 |
Port of Registry: |
Panama |
| 1.9 |
Call sign: |
HOZW |
| 1.10 |
Vessel's satcom phone number: |
335793410 |
| Vessel's fax number: |
335793412 |
| Vessel's telex number: |
335793410 |
| Vessel's email address: |
nordstream@marine-onair.net |
| 1.11 |
Type of vessel: |
Oil Tanker |
| 1.12 |
Type of hull: |
Double Hull |
| 1.13 |
Classification society: |
Nipon Kaiji Kyokai |
| 1.14 |
Class notation: |
NK NS*MNS*MC |
| 1.15 |
If Classification society changed, name of previous society: |
N/A |
| 1.16 |
If Classification society changed, date of change: |
Not Applicable |
| 1.17 |
IMO type, if applicable: |
|
| 1.18 |
Does the vessel have ice class? If yes, state what level: |
N/A , n/a |
| 1.19 |
Date / place of last dry-dock: |
Apr 15, 2008 |
N/A |
| 1.20 |
Date next dry dock due |
Apr 14, 2011 |
| 1.21 |
Date of last special survey / next survey due: |
Apr 15, 2008 |
Apr 09, 2013 |
| 1.22 |
Date of last annual survey: |
Mar 27, 2009 |
| 1.23 |
If ship has Condition Assessment Program (CAP), what is the latest overall rating: |
0 |
| 1.24 |
Does the vessel have a statement of compliance issued under the provisions of the Condition Assessment Scheme (CAS): If yes, what is the expiry date? |
N/A |
| 1.25 |
Length Over All (LOA): |
179.88 M |
| 1.26 |
Length Between Perpendiculars (LBP): |
172 M |
| 1.27 |
Extreme breadth (Beam): |
32.228 M |
| 1.28 |
Moulded depth: |
18.7 M |
| 1.29 |
Keel to Masthead (KTM) / KTM in collapsed condition (if applicable): |
46.055 M |
M |
| 1.30 |
Bow to Center Manifold (BCM) / Stern to Center Manifold (SCM): |
91.29 M |
88.61 M |
| 1.31 |
Distance bridge front to center of manifold: |
54.53 M |
| 1.32 |
Parallel body distances: |
Lightship |
Normal Ballast |
Summer Dwt |
| Forward to mid-point manifold: |
38.32 M |
47.04 M |
47.04 M |
| Aft to mid-point manifold: |
25.12 M |
36.22 M |
47.44 M |
| Parallel body length: |
63.44 M |
83.26 M |
94.48 M |
| 1.33 |
FWA at summer draft / TPC immersion at summer draft: |
270 MM |
50.65 MT |
| 1.34 |
What is the max height of mast above waterline (air draft) |
Full Mast |
Collapsed Mast |
| Lightship: |
43.813 M |
0.000 M |
| Normal ballast: |
39.183 M |
0.000 M |
| At loaded summer deadweight: |
34.033 M |
0.000 M |
| 1.35 |
Net Tonnage: |
11645 |
| 1.36 |
Gross Tonnage / Reduced Gross Tonnage (if applicable): |
28059 |
|
| 1.37 |
Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): |
29370.36 |
26451.08 |
| 1.38 |
Panama Canal Net Tonnage (PCNT): |
23314 |
| 1.39 |
Loadline |
Freeboard |
Draft |
Deadweight |
Displacement |
| Summer: |
6.714 M |
12.022 M |
45974 MT |
54781 MT |
| Winter: |
6.964 M |
11.772 M |
44709 MT |
53516 MT |
| Tropical: |
6.464 M |
12.271 M |
47241 MT |
56048 MT |
| Lightship: |
16.494 M |
2.242 M |
|
8807 MT |
| Normal Ballast Condition: |
11.864 M |
6.872 M |
20748 MT |
29555 MT |
| 1.40 |
Does vessel have multiple SDWT? |
Yes |
| 1.41 |
If yes, what is the maximum assigned deadweight? |
45974 MT |
| 1.42 |
Registered owner - Full style: |
SQ MARINE, S.A. 53rd Street, Urbanizcion Obarrio,Torre Swiss Bank, 16 Floor, Panama, Republic of panama Tel: c/o OMC 813 6665 913 Fax: c/o OMC 813 5523 685 Telex: c/o OMC, 5194078499T Email: omcnordstreamtkzok@dg.mitsui.com |
| 1.43 |
Technical operator - Full style: |
Orient Marine Co.,Ltd Marunouchi Trust Tower North 18th floor 1-8-1 Marunouchi, Chiyoda-ku, Tokyo 100-0005, Japan Tel: 81-3-6665-9130 Fax: 81-3-5223-6851 Telex: 5194078499TOYOG Email: tkzok@dg.mitsui.com |
| 1.44 |
Commercial operator - Full style: |
Norient Product Pool A/S 49 Amaliegade,DK-1256 Copenhagen K,Denmark Tel: +45-3271-2300 Fax: +45-33271-2349 Telex: 055-15103 NORIENT DK Email: largeoperation@norientpool.com |
| 1.45 |
Disponent owner - Full style: |
Orient Marine Co.,Ltd HIBIYA DAI BLDG, 14th Floor,1-2-2, Uchisaiwai-cho, Chiyodaku, Tokyo 100-0011, Japan Tel: 81-3-5501-9114 Fax: 81-3-5501-9167 Telex: 5194078499TOYOG Email: tkzok@dg.mitsui.com |
| |
| 2.1 |
Safety Equipment Certificate: |
May 28, 2009 |
Mar 27, 2009 |
Apr 09, 2013 |
| 2.2 |
Safety Radio Certificate: |
May 29, 2008 |
Mar 27, 2009 |
Apr 09, 2013 |
| 2.3 |
Safety Construction Certificate: |
May 29, 2008 |
Mar 27, 2009 |
Apr 09, 2013 |
| 2.4 |
Loadline Certificate: |
May 29, 2008 |
Mar 27, 2009 |
Apr 09, 2013 |
| 2.5 |
International Oil Pollution Prevention Certificate (IOPPC): |
May 29, 2008 |
Mar 27, 2009 |
Apr 09, 2013 |
| 2.6 |
Safety Management Certificate (SMC): |
Nov 24, 2009 |
Not Applicable |
Jan 09, 2014 |
| 2.7 |
Document of Compliance (DOC): |
Nov 24, 2009 |
Aug 13, 2009 |
Jul 09, 2011 |
| 2.8 |
USCG (specify: COC, LOC or COI): COC |
Feb 23, 2010 |
|
Feb 23, 2012 |
| 2.9 |
Civil Liability Convention Certificate (CLC): |
Feb 20, 2010 |
|
Feb 20, 2011 |
| 2.10 |
Civil Liability for Bunker Oil Pollution Damage Convention Certificate (CLBC): |
Feb 20, 2010 |
|
Feb 20, 2011 |
| 2.11 |
U.S. Certificate of Financial Responsibility (COFR): |
Oct 08, 2007 |
|
Oct 08, 2010 |
| 2.12 |
Certificate of Fitness (Chemicals): |
Not Applicable |
|
Not Applicable |
| 2.13 |
Certificate of Fitness (Gas): |
Not Applicable |
|
Not Applicable |
| 2.14 |
Certificate of Class: |
May 29, 2008 |
Mar 27, 2009 |
Apr 10, 2013 |
| 2.15 |
International Ship Security Certificate (ISSC): |
Jan 10, 2009 |
|
Jan 10, 2014 |
| 2.16 |
International Sewage Pollution Prevention Certificate (ISPPC) |
May 29, 2008 |
|
Apr 09, 2013 |
| 2.17 |
International Air Pollution Prevention Certificate (IAPP): |
May 29, 2008 |
|
Apr 09, 2013 |
| 2.18 |
Does vessel have all updated publications as listed in the Vessel Inspection Questionnaire, Chapter 2- Question 2.24, as applicable: |
Yes |
| 2.19 |
Owner warrant that vessel is member of ITOPF and will remain so for the entire duration of this voyage/contract: |
Yes |
| |
| 3.1 |
Nationality of Master: |
Korea |
| 3.2 |
Nationality of Officers: |
Korean/4,Filipino/4 |
| 3.3 |
Nationality of Crew: |
Filipino/13 |
| 3.4 |
If Officers/Crew employed by a Manning Agency - Full style: |
Officers: Iino Marine Service Co., Ltd Shiba-Daimon Front Bldg, 1-7-13, Shiba-Kouen, Minato-Ku, Tokyo 105-0011, Japan. Tel: 81-3 5408 0295 Fax: 81-3-5408-0309 Telex: J22238 Email: seninf@ex.iino.co.jp Crew: Pobar Marine Service Inc. Rm 501/502,5th Floor Ermita center Bldg.,1350,Roxas Blvd,Ermita Manila 1000 Tel: 63-2-521-4809/9371 Fax: 63-2-521-2607 Email: pmsi@pobar.co.ph |
| 3.5 |
What is the common working language onboard: |
English |
| 3.6 |
Do officers speak and understand English: |
Yes |
| 3.7 |
In case of Flag Of Convenience, is the ITF Special Agreement on board: |
N/A |
| |
| 4.1 |
Can the ship comply with the ICS Helicopter Guidelines: |
N/A |
| 4.2 |
If Yes, state whether winching or landing area provided: |
|
| |
| 5.1 |
Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Guard which has been approved by official USCG letter: |
Yes |
| 5.2 |
Qualified individual (QI) - Full style: |
ECM Maritime Service LLC 64, Danbury Road, Wilton, CT 06897 Tel: +203-761-6030 / +281 Fax: +203-761-6085 |
| 5.3 |
Oil Spill Response Organization (OSRO) -Full style: |
Marine Spill Responce Corp N/A Tel: 800-645-7745 / 732-4 Fax: 800-635-6772 / 732-4 Telex: N/A |
| 5.4 |
Has technical operator signed the SCIA / C-TPAT agreement with US customs concerning drug smuggling: |
Yes |
| |
| 6.1 |
Is vessel fitted with centerline bulkhead in all cargo tanks: |
Yes |
| 6.2 |
If Yes, is bulkhead solid or perforated: |
Solid |
| 6.3 |
Capacity (98%) of each natural segregation with double valve (specify tanks): |
|
| 6.4 |
Total cubic capacity (98%, excluding slop tanks): |
50753.5 M3 |
| 6.5 |
Slop tank(s) capacity (98%): |
1745.9 M3 |
| 6.6 |
Residual/Retention oil tank(s) capacity (98%), if applicable: |
M3 |
| 6.7 |
Does vessel have Segregated Ballast Tanks (SBT) or Clean Ballast Tanks (CBT): |
SBT |
| 6.8 |
What is total capacity of SBT? |
20183.53 M3 |
| 6.9 |
What percentage of SDWT can vessel maintain with SBT only: |
44 % |
| 6.10 |
Does vessel meet the requirements of MARPOL Annex I Reg 18.2: (previously Reg 13.2) |
Yes |
| 6.11 |
How many grades/products can vessel load/discharge with double valve segregation: |
4 |
| 6.12 |
Maximum loading rate for homogenous cargo per manifold connection: |
2000 M3/HR |
| 6.13 |
Maximum loading rate for homogenous cargo loaded simultaneously through all manifolds: |
5832 M3/HR |
| 6.14 |
Are there any cargo tank filling restrictions. If yes, please specify: |
N/A Not Applicable |
| 6.15 |
Pumps: |
No. |
Type |
Capacity |
| Cargo: |
10 |
Centrifugal |
1000 M3/HR |
| Stripping: |
1 |
Reciprocating |
150 M3/HR |
| Eductors: |
1 |
Positive Displacment |
150 M3/HR |
| Ballast: |
1 |
Centrifugal |
1400 M3/HR |
| 6.16 |
How many cargo pumps can be run simultaneously at full capacity: |
3 |
| 6.17 |
Is ship fitted with a Cargo Control Room (CCR): |
Yes |
| 6.18 |
Can tank innage / ullage be read from the CCR: |
No |
| 6.19 |
Can ship operate under closed conditions in accordance with ISGOTT: |
Yes |
| 6.20 |
What type of fixed closed tank gauging system is fitted: |
Floating |
| 6.21 |
Are overfill (high-high) alarms fitted? If Yes, indicate whether to all tanks or partial: |
All |
| 6.22 |
Is a vapor return system (VRS) fitted: |
Yes |
| 6.23 |
Number/size of VRS manifolds (per side): |
2 |
MM |
| 6.24 |
State what type of venting system is fitted: |
Independent + COMMON |
| 6.25 |
Does vessel comply with the latest edition of the OCIMF 'Recommendations for Oil Tanker Manifolds and Associated Equipment': |
Yes |
| 6.26 |
What is the number of cargo connections per side: |
4 |
| 6.27 |
What is the size of cargo connections: |
300 MM |
| 6.28 |
What is the material of the manifold: |
Steel |
| 6.29 |
Distance between cargo manifold centers: |
2000 MM |
| 6.30 |
Distance ships rail to manifold: |
4350 MM |
| 6.31 |
Distance manifold to ships side: |
4600 MM |
| 6.32 |
Top of rail to center of manifold: |
941 MM |
| 6.33 |
Distance main deck to center of manifold: |
2100 MM |
| 6.34 |
Manifold height above the waterline in normal ballast / at SDWT condition: |
13.892 M |
8.786 M |
| 6.35 |
Number / size reducers: |
4 x 300/150mm (12/6") 4 x 300/200mm (12/8") 4 x 300/250mm (12/10") 8 x 400/300mm (16/12") 4 x 300/300mm (12/12") |
| 6.36 |
Is vessel fitted with a stern manifold: |
No |
| 6.37 |
If stern manifold fitted, state size: |
MM |
| 6.38 |
Type of cargo heating system? |
Heating coils |
| 6.39 |
If fitted, are all tanks coiled? |
Yes |
| 6.40 |
If fitted, what is the material of the heating coils: |
Stainless Steel |
| 6.41 |
Maximum temperature cargo can be loaded/maintained: |
75.0 °C / 167.0 °F |
75 °C / 167 °F |
| 6.42 |
Are cargo, ballast and slop tanks coated? |
Coated |
Type |
To What Extent |
| Cargo tanks: |
Yes |
Pure Epoxy Paint |
Whole Tank |
| Ballast tanks: |
Yes |
Tar Expoxy |
Whole |
| Slop tanks: |
Yes |
Pure epoxy |
Whole Tank |
| 6.43 |
If fitted, what type of anodes are used: |
ZN Anode |
| |
| 7.1 |
Is an Inert Gas System (IGS) fitted: |
Yes |
| 7.2 |
Is IGS supplied by flue gas, inert gas (IG) generator and/or nitrogen: |
Flue Gas |
| 7.3 |
Is a Crude Oil Washing (COW) installation fitted: |
N/A |
| |
| 8.1 |
Mooring wires (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
MM |
Not Applicable |
M |
MT |
| Main deck fwd: |
2 |
28 MM |
IWRC 6 X 36 |
220 M |
44.5 MT |
| Main deck aft: |
2 |
28 MM |
IWRC 6 X 36 |
220 M |
44.5 MT |
| Poop deck: |
|
MM |
Not Applicable |
M |
MT |
| 8.2 |
Wire tails |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
MM |
Not Applicable |
M |
MT |
| Main deck fwd: |
2 |
60 MM |
CE Compound |
11 M |
83 MT |
| Main deck aft: |
2 |
60 MM |
CE Compound |
11 M |
83 MT |
| Poop deck: |
|
MM |
Not Applicable |
M |
MT |
| 8.3 |
Mooring ropes (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
4 |
65 MM |
CE Compound |
227 M |
61.9 MT |
| Main deck fwd: |
|
MM |
Not Applicable |
M |
MT |
| Main deck aft: |
|
MM |
Not Applicable |
M |
MT |
| Poop deck: |
4 |
65 MM |
CE Compound |
227 M |
61.9 MT |
| 8.4 |
Other mooring lines |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
3 |
65 MM |
CE Compound |
227 M |
61.9 MT |
| Main deck fwd: |
|
MM |
Not Applicable |
M |
MT |
| Main deck aft: |
|
MM |
Not Applicable |
M |
MT |
| Poop deck: |
4 |
65 MM |
CE Compound |
227 M |
61.9 MT |
| 8.5 |
Mooring winches |
No. |
# Drums |
Brake Capacity |
| Forecastle: |
2 |
Double Drums |
35.7 MT |
| Main deck fwd: |
1 |
Double Drums |
35.7 MT |
| Main deck aft: |
2 |
Single Drum |
35.7 MT |
| Poop deck: |
2 |
Double Drums |
35.7 MT |
| 8.6 |
Mooring bitts |
No. |
SWL |
| Forecastle: |
6 |
64 MT |
| Main deck fwd: |
6 |
62.8 MT |
| Main deck aft: |
8 |
62.8 MT |
| Poop deck: |
8 |
64 MT |
| 8.7 |
Closed chocks and/or fairleads of enclosed type |
No. |
SWL |
| Forecastle: |
5 |
60 MT |
| Main deck fwd: |
8 |
39.5 MT |
| Main deck aft: |
10 |
39.5 MT |
| Poop deck: |
12 |
39.5 MT |
| 8.8 |
Type / SWL of Emergency Towing system forward: |
TATENO-KASHIWA / TK40F |
204 MT |
| 8.9 |
Type / SWL of Emergency Towing system aft: |
TATENOKASHIWA / TK20A |
102 MT |
| 8.10 |
Number of shackles on port cable: |
|
| 8.11 |
Number of shackles on starboard cable: |
|
| 8.12 |
What is SWL and size of closed chock and/or fairleads of enclosed type on stern: |
100 MT |
400 x 260 |
| 8.13 |
What is SWL of bollard on poopdeck suitable for escort tug: |
64 MT |
| 8.14 |
What is brake horse power of bow thruster (if fitted): |
BHP |
0 KW |
| 8.15 |
What is brake horse power of stern thruster (if fitted): |
BHP |
0 KW |
| 8.16 |
Does vessel comply with the latest edition of OCIMF 'Recommendations for Equipment Employed in the Mooring of Vessels at Single Point Moorings (SPM)': |
Yes |
| 8.17 |
Is vessel fitted with chain stopper(s): |
Yes |
| 8.18 |
How many chain stopper(s) are fitted: |
1 |
| 8.19 |
State type of chain stopper(s) fitted: |
HINGE TYPE |
| 8.20 |
Safe Working Load (SWL) of chain stopper(s): |
200 MT |
| 8.21 |
What is the maximum size chain diameter the bow stopper(s) can handle: |
76 MM |
| 8.22 |
Distance between the bow fairlead and chain stopper/bracket: |
2700 MM |
| 8.23 |
Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm x 450mm)? If not, give details of size: |
Yes |
| 8.24 |
Derrick / Crane description (Number, SWL and location): |
Cranes: 1 x 10 Tonnes |
| 8.25 |
What is maximum outreach of cranes / derricks outboard of the ship's side: |
2.886 M |
| 8.26 |
Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Transfer Guide (Petroleum or Liquified Gas, as applicable): |
Yes |
| |
| 9.1 |
What type of fuel is used for main propulsion? |
HFO |
| 9.2 |
What type of fuel is used in the generating plant? |
HFO |
| 9.3 |
Capacity of bunker tanks - IFO and MDO/MGO: |
1849.71 M3 |
91.58 M3 91.58 M3 |
| 9.4 |
Is vessel fitted with fixed or controllable pitch propeller(s)? |
Fixed Pitch |
| 9.5 |
P & I Club - Full Style: |
JAPAN CLUB |
| 9.6 |
P & I Club coverage - pollution liability coverage: |
1000000000 US$ |
| 9.7 |
Date and place of last Port State Control inspection: |
Oct 12, 2007 / Batangas, Philippines |
| 9.8 |
Any outstanding deficiencies as reported by any Port State Control: |
No |
| 9.9 |
If yes, provide details: |
None |
| 9.10 |
Has vessel been involved in a pollution, grounding, serious casualty or collision incident during the past 12 months? If yes, full description: |
Pollution: No , N/A Grounding: No , N/A Serious casualty: , Collision: No , N/A |
| 9.11 |
Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last): |
Contact owner for details |
| 9.12 |
Date/Place of last SIRE Inspection: |
Feb 26, 2010 / Honolulu |
| 9.13 |
Date/Place of last CDI Inspection: |
/ |
| 9.14 |
Recent Oil company inspections/screenings (To the best of owners knowledge and without guarantee of acceptance for future business)*:
*Blanket "approvals" are no longer given by Oil Majors and ships are accepted for the voyage on a case by case basis. |
Contact owner for details. |