| 1.1 |
Date updated: |
Feb 01, 2012 |
| 1.2 |
Vessel's name: |
Nord Sea |
| 1.3 |
IMO number: |
9315068 |
| 1.4 |
Vessel's previous name(s) and date(s) of change: |
Gan Shield (Apr 09, 2010) |
| 1.5 |
Date delivered: |
Jan 04, 2007 |
| 1.6 |
Builder (where built): |
STX SHIPBUILDING CO.LTD. |
| 1.7 |
Flag: |
Singapore |
| 1.8 |
Port of Registry: |
Singapore |
| 1.9 |
Call sign: |
9V8578 |
| 1.10 |
Vessel's satcom phone number: |
764951094 |
| Vessel's fax number: |
764951095 |
| Vessel's telex number: |
456587111/ 456587112 |
| Vessel's email address: |
nord_sea@amosconnect.com |
| 1.11 |
Type of vessel: |
Oil-Chemical (IMO III)Tanker |
| 1.12 |
Type of hull: |
Double Hull |
| 1.13 |
Classification society: |
Det Norske Veritas |
| 1.14 |
Class notation: |
+1A1 Tanker for Oil/Chemical, ESP, Ship Type III, E0, T-MON, (S,I),Nauticus, Plus 1, SPM, Clean, VCS-2, ETC |
| 1.15 |
If Classification society changed, name of previous society: |
No |
| 1.16 |
If Classification society changed, date of change: |
Not Applicable |
| 1.17 |
IMO type, if applicable: |
3 |
| 1.18 |
Does the vessel have ice class? If yes, state what level: |
No , |
| 1.19 |
Date / place of last dry-dock: |
Dec 10, 2010 |
Lisnave, Portugal |
| 1.20 |
Date next dry dock due |
Not Applicable |
| 1.21 |
Date of last special survey / next survey due: |
Dec 13, 2011 |
Jan 02, 2017 |
| 1.22 |
Date of last annual survey: |
Dec 13, 2011 |
| 1.23 |
If ship has Condition Assessment Program (CAP), what is the latest overall rating: |
(N/A) |
| 1.24 |
Does the vessel have a statement of compliance issued under the provisions of the Condition Assessment Scheme (CAS): If yes, what is the expiry date? |
N/A |
| 1.25 |
Length Over All (LOA): |
183 m |
| 1.26 |
Length Between Perpendiculars (LBP): |
173.9 m |
| 1.27 |
Extreme breadth (Beam): |
32.23 m |
| 1.28 |
Moulded depth: |
19.1 m |
| 1.29 |
Keel to Masthead (KTM) / KTM in collapsed condition (if applicable): |
46.03 m |
46.03 m |
| 1.30 |
Bow to Center Manifold (BCM) / Stern to Center Manifold (SCM): |
92.592 m |
90.41 m |
| 1.31 |
Distance bridge front to center of manifold: |
56.26 m |
| 1.32 |
Parallel body distances: |
Lightship |
Normal Ballast |
Summer Dwt |
| Forward to mid-point manifold: |
25.2 m |
44.1 m |
44.1 m |
| Aft to mid-point manifold: |
31.8 m |
45.5 m |
58.1 m |
| Parallel body length: |
57 m |
89.6 m |
102.2 m |
| 1.33 |
FWA at summer draft / TPC immersion at summer draft: |
290 mm |
52 MT |
| 1.34 |
What is the max height of mast above waterline (air draft) |
Full Mast |
Collapsed Mast |
| Lightship: |
43.469 m |
0.000 m |
| Normal ballast: |
39.07 m |
0.000 m |
| At loaded summer deadweight: |
33.160 m |
0.000 m |
| 1.35 |
Net Tonnage: |
13648 |
| 1.36 |
Gross Tonnage / Reduced Gross Tonnage (if applicable): |
30068 |
22782 |
| 1.37 |
Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): |
31209.92 |
26369.02 |
| 1.38 |
Panama Canal Net Tonnage (PCNT): |
13648 |
| 1.39 |
Loadline |
Freeboard |
Draft |
Deadweight |
Displacement |
| Summer: |
6.23 m |
12.87 m |
49759 MT |
59965 MT |
| Winter: |
6.498 m |
12.602 m |
48367.284 MT |
58573.284 MT |
| Tropical: |
5.962 m |
13.138 m |
51150.972 MT |
61356.972 MT |
| Lightship: |
16.569 m |
2.561 m |
|
10206 MT |
| Normal Ballast Condition: |
12.17 m |
6.960 m |
20076 MT |
30282 MT |
| 1.40 |
Does vessel have multiple SDWT? |
Yes |
| 1.41 |
If yes, what is the maximum assigned deadweight? |
51213 MT |
| 1.42 |
Registered owner - Full style: |
NORDEN Shipping (Singapore) Pte Ltd Norden shipping (Singapore) Pte Ltd
6, Temasek Boulevard
#27-05 Suntec Tower Four
Singapore 038986 Tel: +65 6395 4233 Fax: +65 6235 0567 Telex: Not Applicable Email: tankops@ds-norden.com |
| 1.43 |
Technical operator - Full style: |
D/S Norden A/S Strandvejen 52 DK-2900 Hellerup Denmark Tel: +45 33150451 Fax: +45 33931599 Telex: Not Applicable Email: tankops@ds-norden.com Web: www.ds-norden.com Company IMO#: 0310059 |
| 1.44 |
Commercial operator - Full style: |
Dampskibsselskabet Norden A/S Strandvejen 52 2900 Hellerup,Denmark Tel: +45 33150451 Fax: +45 33931599 Telex: Not Applicable Email: tankops@ds-norden.com Web: www.norientpool.com |
| 1.45 |
Disponent owner - Full style: |
Norden Shipping (Singapore) Pte Ltd Norient product pool A/s as agent to owner
Strandvejen 52 DK-2900 Hellerup Denmark Tel: +45 3271 2300 Fax: +45 3271 2349 Email: operation@norientpool.com |
| |
| 2.1 |
Safety Equipment Certificate: |
Jan 07, 2011 |
Dec 13, 2011 |
May 13, 2012 |
| 2.2 |
Safety Radio Certificate: |
May 04, 2010 |
Dec 13, 2011 |
May 13, 2012 |
| 2.3 |
Safety Construction Certificate: |
Jan 07, 2011 |
Dec 13, 2011 |
May 13, 2012 |
| 2.4 |
Loadline Certificate: |
Apr 22, 2010 |
Dec 22, 2010 |
May 13, 2012 |
| 2.5 |
International Oil Pollution Prevention Certificate (IOPPC): |
Jan 07, 2011 |
Dec 13, 2011 |
May 13, 2012 |
| 2.6 |
Safety Management Certificate (SMC): |
Jan 06, 2011 |
Not Applicable |
Sep 07, 2015 |
| 2.7 |
Document of Compliance (DOC): |
Jun 30, 2008 |
Jun 10, 2011 |
Mar 18, 2013 |
| 2.8 |
USCG (specify: COC, LOC or COI): COC |
Jun 05, 2010 |
Jul 26, 2011 |
Jun 05, 2012 |
| 2.9 |
Civil Liability Convention Certificate (CLC): |
Feb 20, 2011 |
|
Feb 20, 2012 |
| 2.10 |
Civil Liability for Bunker Oil Pollution Damage Convention Certificate (CLBC): |
Jan 24, 2011 |
|
Feb 20, 2012 |
| 2.11 |
U.S. Certificate of Financial Responsibility (COFR): |
Mar 16, 2010 |
|
Mar 16, 2013 |
| 2.12 |
Certificate of Fitness (Chemicals): |
Jan 03, 2011 |
|
Apr 01, 2012 |
| 2.13 |
Certificate of Fitness (Gas): |
Not Applicable |
|
|
| 2.14 |
Certificate of Class: |
Dec 13, 2011 |
Dec 13, 2011 |
Oct 04, 2016 |
| 2.15 |
International Ship Security Certificate (ISSC): |
Sep 07, 2010 |
|
Sep 07, 2015 |
| 2.16 |
International Sewage Pollution Prevention Certificate (ISPPC) |
Sep 07, 2010 |
|
Apr 01, 2012 |
| 2.17 |
International Air Pollution Prevention Certificate (IAPP): |
Jul 16, 2010 |
|
Apr 01, 2012 |
| 2.18 |
Does vessel have all updated publications as listed in the Vessel Inspection Questionnaire, Chapter 2- Question 2.24, as applicable: |
Yes |
| 2.19 |
Owner warrant that vessel is member of ITOPF and will remain so for the entire duration of this voyage/contract: |
Yes |
| |
| 3.1 |
Nationality of Master: |
Indian |
| 3.2 |
Nationality of Officers: |
INDIAN |
| 3.3 |
Nationality of Crew: |
ALL INDIANS |
| 3.4 |
If Officers/Crew employed by a Manning Agency - Full style: |
Officers: EXECUTIVE SHIP MANAGEMENT Executive Ship Management Pte Ltd
5 Shenton Way,
#20-00, UIC Building
Singapore 068808 Tel: +65 63240500 Fax: +65 63244544 Email: crew@executiveship.com Crew: Executive Ship Management Pte Ltd 5 Shenton Way,
#20-00, UIC Building
Singapore 068808 Tel: Tel : +65 63240500 Fax: Fax : +65 63244544 Telex: Not Applicable Email: Email : crew@executiveship.com |
| 3.5 |
What is the common working language onboard: |
English |
| 3.6 |
Do officers speak and understand English: |
Yes |
| 3.7 |
In case of Flag Of Convenience, is the ITF Special Agreement on board: |
No |
| |
| 4.1 |
Can the ship comply with the ICS Helicopter Guidelines: |
Yes |
| 4.2 |
If Yes, state whether winching or landing area provided: |
Winching |
| |
| 5.1 |
Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Guard which has been approved by official USCG letter: |
Yes |
| 5.2 |
Qualified individual (QI) - Full style: |
Gallagher Marine Systems 100 Century Parkway
Suite 130 Mount Laurel,
NJ 08054, USA Tel: +1 856 642 2091 Email: info@chgms.com |
| 5.3 |
Oil Spill Response Organization (OSRO) -Full style: |
National Response Corporation 3500 Sunrise Hwy Ste. T103
Great River, NY 11739 Tel: +1 (631) 224 9141 Fax: +1 (631) 224-9086 Email: iocdo@nrcc.com Web: www.nrcc.com |
| 5.4 |
Has technical operator signed the SCIA / C-TPAT agreement with US customs concerning drug smuggling: |
Yes |
| |
| 6.1 |
Is vessel fitted with centerline bulkhead in all cargo tanks: |
Yes |
| 6.2 |
If Yes, is bulkhead solid or perforated: |
Solid |
| 6.3 |
Capacity (98%) of each natural segregation with double valve (specify tanks): |
|
| 6.4 |
Total cubic capacity (98%, excluding slop tanks): |
52149.891 m3 |
| 6.5 |
Slop tank(s) capacity (98%): |
2819.410 m3 |
| 6.6 |
Residual/Retention oil tank(s) capacity (98%), if applicable: |
103 m3 |
| 6.7 |
Does vessel have Segregated Ballast Tanks (SBT) or Clean Ballast Tanks (CBT): |
SBT |
| 6.8 |
What is total capacity of SBT? |
24154.7 m3 |
| 6.9 |
What percentage of SDWT can vessel maintain with SBT only: |
48 % |
| 6.10 |
Does vessel meet the requirements of MARPOL Annex I Reg 18.2: (previously Reg 13.2) |
Yes |
| 6.11 |
How many grades/products can vessel load/discharge with double valve segregation: |
7 |
| 6.12 |
Maximum loading rate for homogenous cargo per manifold connection: |
2500 m3/hr |
| 6.13 |
Maximum loading rate for homogenous cargo loaded simultaneously through all manifolds: |
4200 m3/hr |
| 6.14 |
Are there any cargo tank filling restrictions. If yes, please specify: |
Yes Max. SG.1.53 FILLING MAX 66.7 pct of Tank Height |
| 6.15 |
Pumps: |
No. |
Type |
Capacity |
| Cargo: |
12 2 1 1 |
Centrifugal Centrifugal Centrifugal-FRAMO Centrifugal-FRAMO |
600 M3/HR 300 M3/HR 150 M3/HR 20 M3/HR |
| Stripping: |
0 |
|
0 m3/hr |
| Eductors: |
0 |
|
0 m3/hr |
| Ballast: |
2 |
Centrifugal |
750 m3/hr |
| 6.16 |
How many cargo pumps can be run simultaneously at full capacity: |
6 |
| 6.17 |
Is ship fitted with a Cargo Control Room (CCR): |
Yes |
| 6.18 |
Can tank innage / ullage be read from the CCR: |
Yes |
| 6.19 |
Can ship operate under closed conditions in accordance with ISGOTT: |
Yes |
| 6.20 |
What type of fixed closed tank gauging system is fitted: |
Radar |
| 6.21 |
Are overfill (high-high) alarms fitted? If Yes, indicate whether to all tanks or partial: |
ALL CARGO TANKS ARE FITTED WITH HL-HHL ALARMS |
| 6.22 |
Is a vapor return system (VRS) fitted: |
Yes |
| 6.23 |
Number/size of VRS manifolds (per side): |
2 |
300 mm |
| 6.24 |
State what type of venting system is fitted: |
High Velocity |
| 6.25 |
Does vessel comply with the latest edition of the OCIMF 'Recommendations for Oil Tanker Manifolds and Associated Equipment': |
Yes |
| 6.26 |
What is the number of cargo connections per side: |
7 |
| 6.27 |
What is the size of cargo connections: |
350 mm |
| 6.28 |
What is the material of the manifold: |
SUS 316 |
| 6.29 |
Distance between cargo manifold centers: |
2000 mm |
| 6.30 |
Distance ships rail to manifold: |
4600 mm |
| 6.31 |
Distance manifold to ships side: |
4600 mm |
| 6.32 |
Top of rail to center of manifold: |
900 mm |
| 6.33 |
Distance main deck to center of manifold: |
2100 mm |
| 6.34 |
Manifold height above the waterline in normal ballast / at SDWT condition: |
13.78 m |
8.06 m |
| 6.35 |
Number / size reducers: |
12 x 400/350mm (16/14") 2 x 400/200mm (16/8") 6 x 350/300mm (14/12") 6 x 350/250mm (14/10") 6 x 350/200mm (14/8") |
| 6.36 |
Is vessel fitted with a stern manifold: |
No |
| 6.37 |
If stern manifold fitted, state size: |
mm |
| 6.38 |
Type of cargo heating system? |
HEAT EXCHANGER |
| 6.39 |
If fitted, are all tanks coiled? |
No |
| 6.40 |
If fitted, what is the material of the heating coils: |
|
| 6.41 |
Maximum temperature cargo can be loaded/maintained: |
60.0 °C / 140.0 °F |
60 °C / 140 °F |
| 6.42 |
Are cargo, ballast and slop tanks coated? |
Coated |
Type |
To What Extent |
| Cargo tanks: |
Yes |
Epoxy |
Whole Tank |
| Ballast tanks: |
Yes |
Pure Epoxy |
Whole Tank |
| Slop tanks: |
|
PURE EPOXY |
Whole Tank |
| 6.43 |
If fitted, what type of anodes are used: |
Zinc ANODES |
| |
| 7.1 |
Is an Inert Gas System (IGS) fitted: |
Yes |
| 7.2 |
Is IGS supplied by flue gas, inert gas (IG) generator and/or nitrogen: |
IG Generator |
| 7.3 |
Is a Crude Oil Washing (COW) installation fitted: |
Yes |
| |
| 8.1 |
Mooring wires (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
mm |
Not Applicable |
m |
MT |
| Main deck fwd: |
4 |
35 mm |
6 x 37 IWRC |
220 m |
77 MT |
| Main deck aft: |
4 |
35 mm |
6 x 37 IWRC |
220 m |
77 MT |
| Poop deck: |
0 |
0 mm |
|
0 m |
0 MT |
| 8.2 |
Wire tails |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
mm |
Not Applicable |
m |
MT |
| Main deck fwd: |
4 |
80 mm |
Nylon |
11 m |
121 MT |
| Main deck aft: |
4 |
80 mm |
Nylon |
11 m |
121 MT |
| Poop deck: |
|
mm |
Not Applicable |
m |
MT |
| 8.3 |
Mooring ropes (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
4 |
65 mm |
Superflex Fiber Rp |
220 m |
79.8 MT |
| Main deck fwd: |
|
mm |
|
m |
MT |
| Main deck aft: |
|
mm |
|
m |
MT |
| Poop deck: |
4 |
65 mm |
Superflex Fiber Rp |
220 m |
79.8 MT |
| 8.4 |
Other mooring lines |
No. |
Diameter |
Material |
Length |
Breaking Strength |
| Forecastle: |
|
mm |
Not Applicable |
m |
MT |
| Main deck fwd: |
|
mm |
Not Applicable |
m |
MT |
| Main deck aft: |
|
mm |
Not Applicable |
m |
MT |
| Poop deck: |
|
mm |
Not Applicable |
m |
MT |
| 8.5 |
Mooring winches |
No. |
# Drums |
Brake Capacity |
| Forecastle: |
2 |
Double Drums |
46.6 MT |
| Main deck fwd: |
2 |
Double Drums |
46.6 MT |
| Main deck aft: |
2 |
Double Drums |
46.6 MT |
| Poop deck: |
2 |
Double Drums |
46.6 MT |
| 8.6 |
Mooring bitts |
No. |
SWL |
| Forecastle: |
6 |
64 MT |
| Main deck fwd: |
4 |
52 MT |
| Main deck aft: |
4 |
52 MT |
| Poop deck: |
8 |
64 MT |
| 8.7 |
Closed chocks and/or fairleads of enclosed type |
No. |
SWL |
| Forecastle: |
9 |
51 MT |
| Main deck fwd: |
12 |
51 MT |
| Main deck aft: |
12 |
51 MT |
| Poop deck: |
14 |
51 MT |
| 8.8 |
Type / SWL of Emergency Towing system forward: |
Chafing chain with Tongue Type Stopper |
200 MT |
| 8.9 |
Type / SWL of Emergency Towing system aft: |
Tanktech-KETSP 40-A |
200 MT |
| 8.10 |
Number of shackles on port cable: |
11 |
| 8.11 |
Number of shackles on starboard cable: |
12 |
| 8.12 |
What is SWL and size of closed chock and/or fairleads of enclosed type on stern: |
200 MT |
650 |
| 8.13 |
What is SWL of bollard on poopdeck suitable for escort tug: |
64 MT |
| 8.14 |
What is brake horse power of bow thruster (if fitted): |
bhp |
0 Kw |
| 8.15 |
What is brake horse power of stern thruster (if fitted): |
bhp |
0 Kw |
| 8.16 |
Does vessel comply with the latest edition of OCIMF 'Recommendations for Equipment Employed in the Mooring of Vessels at Single Point Moorings (SPM)': |
Yes |
| 8.17 |
Is vessel fitted with chain stopper(s): |
Yes |
| 8.18 |
How many chain stopper(s) are fitted: |
1 |
| 8.19 |
State type of chain stopper(s) fitted: |
Tongue Type |
| 8.20 |
Safe Working Load (SWL) of chain stopper(s): |
200 MT |
| 8.21 |
What is the maximum size chain diameter the bow stopper(s) can handle: |
76 mm |
| 8.22 |
Distance between the bow fairlead and chain stopper/bracket: |
3022 mm |
| 8.23 |
Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm x 450mm)? If not, give details of size: |
Yes Not Applicable |
| 8.24 |
Derrick / Crane description (Number, SWL and location): |
Cranes: 1 x 10 Tonnes |
| 8.25 |
What is maximum outreach of cranes / derricks outboard of the ship's side: |
8.8 m |
| 8.26 |
Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Transfer Guide (Petroleum or Liquified Gas, as applicable): |
Yes |
| |
| 9.1 |
What type of fuel is used for main propulsion? |
380 CST FUEL OIL |
| 9.2 |
What type of fuel is used in the generating plant? |
HFO & MGO |
| 9.3 |
Capacity of bunker tanks - IFO and MDO/MGO: |
1568.700 m3 |
0.000 m3 233.500 m3 |
| 9.4 |
Is vessel fitted with fixed or controllable pitch propeller(s)? |
Fixed Pitch |
| 9.5 |
P & I Club - Full Style: |
NORTH OF ENGLAND |
| 9.6 |
P & I Club coverage - pollution liability coverage: |
1000000000 US$ |
| 9.7 |
Date and place of last Port State Control inspection: |
Jul 16, 2011 / Montreal |
| 9.8 |
Any outstanding deficiencies as reported by any Port State Control: |
No |
| 9.9 |
If yes, provide details: |
N/A |
| 9.10 |
Has vessel been involved in a pollution, grounding, serious casualty or collision incident during the past 12 months? If yes, full description: |
Pollution: N/A , N/A Grounding: N/A , In accordance with "Masters Statements" issued by ship's master on 2011-08-10, the fwd stb area of ship was smooth
aground at Amazon River, while she is swing to change of pilot. After approx. 15 minutes the ship resumed her
passage to the Port of Manaus.
Due the bad visibility of Amazon and Black rivers (cloudy waters), it was impossible to carry out an in water survey
in any part of Amazon River.
Due the a.m fact DNV H.O. instructed owner to perform the internal inspection of Double Bottom Ballast Tanks to
verify if grounding cause some indent/damage.
The following items were verified during the survey:
- Internal inspection of all Double Bottom Tanks : DB Tk 1P/S, DB Tk 2P/S, DB Tk 3P/S, DB Tk 4P/S, Fore Peak
(single bottom). Upon completion of internal examination no signal of damage, indent or cracks were observed on
bottom plate and internal structures.
- The sounding of E.R. bilges/tanks and D.B.B. tanks were carried out after grounding and at arrival of ship in
Ita Serious casualty: No , Collision: N/A , N/A |
| 9.11 |
Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last): |
Contact owner for details |
| 9.12 |
Date/Place of last SIRE Inspection: |
Nov 06, 2011 / Rotterdam |
| 9.13 |
Date/Place of last CDI Inspection: |
|
| 9.14 |
Recent Oil company inspections/screenings (To the best of owners knowledge and without guarantee of acceptance for future business)*:
*Blanket "approvals" are no longer given by Oil Majors and ships are accepted for the voyage on a case by case basis. |
Contact owner for details. |